EATON (Menvier) ULCMIO353 UL 120V/230V ac Relay Unit

Model ULCMIO353

Brand
EATON
Models
ULCMIO353
Type
120V/230V ac Relay Unit
Dimensions
129 × 180 × 60 mm
IP rating
IP40
Standard
UL 864 9th ed.
Request a quote for this product
Or buy from the online store

The EATON ULCMIO353 is a 120v/230v ac relay unit from the Eaton UL range interfaces, listed to UL 864 9th edition. Its output switches mains, ideal for plant control or mains door holders; the monitored input suits sprinkler flow switch monitoring.

In short

  • Soft addressed.
  • Dimensions 129 × 180 × 60 mm, IP40.
  • Within the UL listing for control unit accessories (S24988).

What it does

Its output switches mains, ideal for plant control or mains door holders; the monitored input suits sprinkler flow switch monitoring.

Interfaces let a wide variety of installations be simplified without specialist or customised equipment; Eaton technical support helps choose the right one.

Technical data

Technical data — per EATON datasheet Modules
ItemValue
ModelULCMIO353
Type120V/230V ac Relay Unit
Dimensions129 × 180 × 60 mm
IP ratingIP40
StandardUL 864 9th ed.

The critical point: quantity limits and wiring

Quantities and loads are calculated within the panel loop limits, and monitored inputs need their specified end-of-line device.

General notes on interfacing

  • Monitored inputs: sprinkler flow switches connect as alarm inputs and valve tamper switches as supervisory inputs (not alarm), with wiring supervised by an end-of-line resistor.
  • Control outputs: HVAC and fan shutdown, door holder release, elevator recall and access control release are operated through modules or relays per the approved cause & effect.
  • Module proximity: a control module is installed close to the equipment it operates (typically within 3 ft (0.9 m) per NFPA 72), keeping the wiring beyond it short.
  • Relays switching mains voltage keep their wiring segregated from low-voltage wiring, with contact ratings checked against the load.

General engineering notes

These points are general principles from NFPA 72 and common design practice, not from the EATON datasheet. The final decision rests with the project’s approved designer per the adopted edition of the standard and the authority having jurisdiction.

Installation steps

  1. Fit the unit in position.
  2. Wire the loop (in and out) and inputs or outputs per the wiring diagram.
  3. Fit the specified end-of-line resistors on monitored inputs.
  4. Run auto-learn at the panel and test the function.

Common mistakes

  • Forgetting the end-of-line resistor.
  • Exceeding the permitted number per loop.
  • Do not use high-voltage insulation testers while devices or the panel are connected, as the Eaton datasheets warn.

Inspection and maintenance

Before any test or maintenance, notify the owner, the monitoring station and everyone affected, as testing may operate alarms or linked outputs. The owner is responsible for inspection, testing and maintenance per NFPA 72 and the authority having jurisdiction, preferably by a qualified company.

Files and ordering

The EATON UL catalogue and UL certificate are attached. When ordering, state ULCMIO353.

How to order

Use the “Build your order” section on this page: add every model and quantity, then send the whole order by email or WhatsApp. It reaches us as a tidy PDF request sheet and we contact you with the quotation.

FAQ

Does it need manual addressing?

No, it is soft addressed (plug and play).

References

  • EATON Modules — Datasheet (attached)
  • UL 864 — Control Units and Accessories for Fire Alarm Systems
  • NFPA 72 — National Fire Alarm and Signaling Code

This page is general information to help with selection and ordering, taken from the attached EATON datasheet. Final design is set by the project’s approved designer; the project specification, the consultant’s drawings and the latest datasheet revision govern.