Skip to content
Exclusive agent of MECH products in Saudi Arabia
Store Request a quote
Fu-Mech - Future Mechanics Trading Co.
5000+Client
400+Approvals
217Projects
377documented products
16years in Saudi Arabia
UL ListedFM ApprovedVdSLPCBWRASNSFMECH
Made by Fu-Mech

Products we design and build for your tanks and pump rooms

Puddle flanges, anti-vortex plates, vent and feeding pipes, and fittings made to your project drawing. DN50 to DN600, ANSI or PN16 drilling.

  • 16products
  • 4families
  • DN50–600sizes
Sectors

Solutions for every building system

From fire and water networks to HVAC, safety and smart systems. Pick a sector to see its components and products.

All solutions

Fire Protection Systems

  1. BRISTOL Packaged Fire Fighting Pump Set on Skid — Complete System up to 5500 GPM 01 Fire pump Delivers water to the network at the required pressure.
  2. MECH GATE VALVE NRS FLANGE x GROOVE UL RED MODEL Z55X 02 Gate valves Isolate network sections for maintenance.
  3. MECH SWING CHECK VALVE FLANGE RED UL/FM MODEL H44X2 03 Check valve Lets water flow in one direction only.
  4. EATON CFVCEA Emergency Assist Alarm Kit, no PSU 04 Alarm valve & monitoring Signals when sprinklers operate, with flow and supervisory switches.
  5. MECH GROOVED HEAVY COUPLING -MODEL 1NH 05 Grooved couplings & fittings Join pipes quickly without welding.
  6. MECH STAINLESS STEEL Flexible Hose for Sprinkler Connection 06 Flexible sprinkler hoses Connect the sprinkler to the branch line above a suspended ceiling, with no cutting or threading.
Follow the water

From the valve room to the sprinkler

XZ41X · OS&Y GATE VALVE

OS&Y gate valve

The first thing water from the fire pumps meets. The rising stem shows the valve position from a distance, and a tamper switch signals if it is closed.

MECH OS&Y GATE VALVE FLANGE RED UL/FM MODEL XZ41X MECH OS&Y GATE VALVE FLANGE RED UL/FM MODEL…Product page →
ZSFZ · WET ALARM CHECK VALVE

Wet alarm check valve

In the valve room: stops backflow and rings the bell when any sprinkler opens. Its trim carries the pressure gauges, retard chamber, pressure switch and main drain.

MECH FLANGED WET ALARM CHECK VALVE UL RED MODEL ZSFZ4X9 MECH FLANGED WET ALARM CHECK VALVE UL RED…Product page →
XD381X · ZONE CONTROL ASSEMBLY

Zone control assembly

On every floor the zone line leaves the riser: a grooved butterfly valve with a supervisory switch, a flow switch that tells which zone is running, a pressure gauge, and a test & drain valve with a sight glass.

MECH GROOVED BUTTERFLY VALVE WITH TAMPER SWITCH UL/FM RED MODEL XD381X MECH GROOVED BUTTERFLY VALVE WITH TAMPER SWITCH UL/FM…Product page →
1N · GROOVED COUPLINGS & FITTINGS

Grooved couplings and fittings

The riser and mains are grooved throughout: a coupling at every joint, grooved elbows and tees, and mechanical tees for the branch outlets. Fast, weld-free and tolerant of vibration and expansion.

MECH GROOVED FLEXIBLE COUPLING -MODEL 1N MECH GROOVED FLEXIBLE COUPLING -MODEL 1NProduct page →
BMI · THREADED FITTINGS

Threaded BMI fittings

The smaller branch lines are threaded: malleable iron elbows, tees and reducers carry water to every sprinkler.

American Standard MECH BMI ELBOW RED | MODEL 90R American Standard MECH BMI ELBOW RED | MODEL…Product page →
FLEXIBLE SPRINKLER HOSE

Flexible sprinkler hose

In false ceilings a flexible hose links the branch line to the sprinkler and fixes to a bracket on the ceiling grid, so each sprinkler is easy to place.

MECH STAINLESS STEEL Flexible Hose for Sprinkler Connection MECH STAINLESS STEEL Flexible Hose for Sprinkler ConnectionProduct page →
SPRINKLERS

Sprinklers: upright, pendent and sidewall

The last stop. Upright for open ceilings, pendent below false ceilings, sidewall on walls. The bulb breaks at its rated temperature, so water falls only on the fire.

TYCO TY1231 Pendent / Recessed Pendent Sprinkler, K2.8, 1/2″ NPT — TY-FRB TYCO TY1231 Pendent / Recessed Pendent Sprinkler, K2.8,…Product page →
Fire sprinkler system section: valve room, main riser, zone control assemblies, grooved mains, threaded branch lines and sprinklers FLOOR 2 · ZONE 2 FLOOR 1 · ZONE 1 VALVE ROOM MAIN RISER · GROOVED FROM FIRE PUMPSALARM BELLRETARD CHAMBERMAIN DRAINGAUGESSUPERVISORY SWITCHFLOW SWITCHGAUGETEST & DRAINCROSS MAIN · GROOVEDGROOVED END CAPGROOVED ELBOWMECH. TEEFALSE CEILINGBRANCH LINE · THREADEDOPEN CEILING · UPRIGHT SPRINKLERS 1 2 3 4 5 6 7
System lab

Explore the sprinkler system part by part

Tap any part to see what it does and its product, watch what happens in a fire, build your building’s system, or turn it in 3D.

System type
Floors
Ceiling

We take your BOQ as it is, match every line to a listed model, and hand you an approval-ready submittal for the consultant.

How we work

From your BOQ to an approval-ready submittal

Send the BOQ exactly as you received it; we handle the matching and the paperwork.

  1. 01

    Send your BOQ

    Excel, PDF or a photo, as it is.

  2. 02

    We match every line to a listed model

    By size, pressure and required listing, with equivalents for any competitor model in the spec.

  3. 03

    You receive a submittal and a quotation

    Datasheets and certificates for every line in one tidy file.

    Start now
Projects & approvals

A public approvals record, project by project

Each project is documented with its consultant, owner and approval year.

Latest documented approval: July 2026 — Equipment maintenance workshop – King Fahd International Airport, Dammam

  • Riyadh71
  • Dammam & Khobar16
  • Jeddah16
  • Makkah8
  • Jazan7
71 RiyadhRiyadh — 71 16 Dammam & KhobarDammam & Khobar — 16 16 JeddahJeddah — 16 8Makkah — 8 7Jazan — 7 5Madinah — 5 5Qassim — 5 3Jubail — 3 3Tabuk — 3 2Yanbu — 2 2Abha & Khamis — 2 2NEOM — 2 1Hail — 1

Trusted by leading contractors and consultants

Recommendation letters

Approved by the Kingdom's major owners

21 official letters from owners, contractors and consultants across the Kingdom.

All recommendation letters (21)
212projects approved our products
123project owners
110consultants
2013first documented approval

What our clients say

MECH products proved their quality, effectiveness and efficiency, fully complying with the required and approved technical specifications.

Reaal International for Contracting Est.

Al Hayat Hotel Tower — Al Sarhan Tower · Riyadh · 2025

Future Mechanics significantly contributed to completing the project by supplying MECH fire fittings, valves and hangers, with technical support and continuous stock availability.

International For Modern Industries Company (Al-Alameya Group)

Replacement & Renovation of the Firefighting Network and Gas Rooms at Al-Haryq General Hospital · Jeddah · 2026

Some of the owners who approved our products

National Water CompanyTahakomYAMAMMODONSASREF (Saudi Aramco)National Housing CompanyKing Saud bin Abdulaziz University for Health SciencesGeneral Authority of Civil AviationUmm Al Qura for Development & Construction (Masar)LumiZOODSaudi Ground ServicesRiyadh Airports CompanyMinistry of FinanceAl Akaria (Saudi Real Estate)Ministry of National Guard Health AffairsRoyal Commission for Riyadh CitySaudi Real Estate (SRE)Saudi Entertainment Ventures (SEVEN)Red Sea GlobalMouwasat Medical ServicesSecurity Forces HospitalJeddah Central Development Company (JEDCO)Rakaa HoldingNIANLenovoKhaira Mountain Entertainment CompanyJadwa InvestmentESNAMERTH Investment Company
Engineer tools

Live tools. Try them now

Free, no sign-up, and they work on your phone on site.

All tools

Sprinkler flow calculator

56.6L/min
K-factor
Flow56.6 L/min
US15.0 gpm

Q = K × √P

Pipe size converter

Inch6″
DN150
OD mm168.3

Send your BOQ today

We reply with the submittal, the quotation and equivalents for every line.