Fu-Mech Flanged Eccentric Reducer, Model FU-ECC

Model FU-ECC

Manufacturer
Fu-Mech — designed & manufactured
Made to order
Non-standard sizes, lengths and ends to your drawing
Request a quote for this product
Or buy from the online store
Certificates & approvals

Ask us for this product's certificates.

Designed & manufactured by Fu-Mech Sizes DN50 – DN600 ANSI B16.5 or PN16 Made to your project drawing All Fu-Mech products →
Build your order

Configure a model and add it to your order

Pick the product, options and quantity, then "Add to order". Repeat for every model and size, then send the whole order at once: it reaches us as a tidy PDF request sheet and we reply with a quotation.

Model code FU Specification text (for consultants and BOQs)

Open this product →

Your order 0

No lines yet. Configure a model above and press "Add to order". Your order is kept while you browse other product pages.

The Fu-Mech flanged eccentric reducer (model FU-ECC) is fabricated to order to complete tank, pump-room and civil pipework packages. This guide covers where it is used, the critical point in selecting and installing it, and how to order.

At a glance

  • One flat side, offset ends.
  • On a horizontal suction: flat side up.
  • Flanges drilled to ANSI B16.5 or PN16 to order.
  • Made to the two sizes required.

What is it?

A flanged reducer with one flat side, so the two ends are offset. On a horizontal pump suction it is normally fitted flat side up, so no air pocket forms at the top of the pipe ahead of the pump.

Where it is used

  • Horizontal pump suction lines.
  • Fire and water pump rooms.
  • Horizontal runs where air must not collect.

Fitting orientation

Fitting an eccentric reducer upside down (flat side down) on a horizontal suction leaves a pocket at the top where air collects, then passes into the pump and causes cavitation and poor performance.

Caution

Check sizes, flange standard and lengths against the approved piping drawing before fabrication; made-to-order items are built to the data you send.

Fu-Mech fabricated fittings

Fu-Mech fabricated fittings
ItemCode
Duck foot bend 90°FU-DFU
Flanged concentric reducerFU-CON
Flanged eccentric reducer — this productFU-ECC
Double flanged pipeFU-DFP
Pipe sleeveFU-SLV

Flanged fittings and wall sleeves fabricated to complete tank, pump-room and civil pipework packages. Made to your drawing: need a non-standard size, length or end connection? Send us your drawing for a quotation.

How to order

Use the “Build your order” section on this page: add every model, size and quantity, then send the whole order by email or WhatsApp. It reaches us as a tidy PDF request sheet and we contact you with the quotation.

  1. Model code FU-ECC
  2. Large × small size (DN)
  3. Flange standard: ANSI B16.5 or PN16
  4. Quantity, and the drawing if the item is non-standard

Frequently asked questions

Why is the flat side up on a suction line?

So the top of the pipe stays level up to the pump inlet and no air collects. This is established pump-suction piping practice; the approved designer’s details govern.

Which flange standards are available?

Flanges are drilled to ASME B16.5 Class 150 or EN 1092-1 PN16, to match the valves and equipment on your project.

Do you make non-standard items?

Yes. We fabricate non-standard sizes, lengths and end connections to the project drawing. Send the drawing and we send a quotation.

What should I send for a quotation?

Model code FU-ECC, Large × small size (DN), Flange standard: ANSI B16.5 or PN16, Quantity, and the drawing if the item is non-standard.

References

  • ASME B16.5 — Pipe Flanges and Flanged Fittings
  • EN 1092-1 — Steel flanges, PN designated
  • ANSI/HI 9.6.6 — Rotodynamic Pumps for Pump Piping
  • Fu-Mech catalogue — Edition 08/2026 — Other fittings