Skip to content
Exclusive agent of MECH products in Saudi Arabia
Store Request a quote

MECH GROOVED CONCENTRIC REDUCER (THD) MODEL : 240N

Model 240N

Design standard
ASTM F1548, AWWA C606, ISO 6182-12
Material
Ductile iron ASTM A536 Gr. 65-45-12
Coating
Electrophoretic (std.) — epoxy / hot-dip galvanized optional
Sizes
1-1/4" × 1" – 8" × 4" (DN42×25 – DN200×100)
Request a quote for this product
Or buy from the online store
SIZES & DIMENSIONS

Sizes & dimensions

SizeDNPipe OD (mm)Max working pressure (PSI)L Length (mm)Certificate
1-1/4" × 1"DN42×2542.4×33.750064—
1-1/2" × 1"DN48×2548.3×33.750064—
2" × 1/2"DN50×1560.3×21.350064UL / FM / VdS
2" × 3/4"DN50×2060.3×26.950064UL / FM / VdS / LPCB
2" × 1"DN50×2560.3×33.750064UL / FM / VdS / LPCB
2" × 1-1/4"DN50×3260.3×42.450064UL / FM / VdS / LPCB
2" × 1-1/2"DN50×4060.3×48.350064UL / FM / VdS / LPCB
2-1/2" × 1"DN65×2573.0×33.750064UL / FM
2-1/2" × 1"DN65×2573.0×42.450064UL / FM
2-1/2" × 1-1/2"DN65×4073.0×48.350064UL / FM
2-1/2" × 2"DN65×5073.0×60.350064UL / FM
2-1/2" × 1/2"DN65×1576.1×21.350064UL / FM / VdS
2-1/2" × 3/4"DN65×2076.1×26.950064UL / FM / VdS
2-1/2" × 1"DN65×2576.1×33.750064UL / FM / VdS
2-1/2" × 1-1/4"DN65×3276.1×42.450064UL / FM / VdS / LPCB
2-1/2" × 1-1/2"DN65×4076.1×48.350064UL / FM / VdS / LPCB
2-1/2" × 2"DN65×5076.1×60.350064UL / FM / VdS / LPCB
3" × 1/2"DN80×1588.9×21.350064UL / FM / VdS
3" × 3/4"DN80×2088.9×26.950064UL / FM / VdS
3" × 1"DN80×2588.9×33.750064UL / FM / VdS
3" × 1-1/4"DN80×3288.9×42.450064UL / FM / VdS
3" × 1-1/2"DN80×4088.9×48.350064UL / FM / VdS
3" × 2"DN80×5088.9×60.350064UL / FM / VdS / LPCB
3" × 2-1/2"DN80×6588.9×73.050064UL / FM
3" × 2-1/2"DN80×6588.9×76.150064UL / FM / VdS / LPCB
4" × 1"DN100×25108.0×33.750076UL / FM
4" × 1-1/4"DN100×32108.0×42.450076UL / FM
4" × 1-1/2"DN100×40108.0×48.350076UL / FM
4" × 2"DN100×50108.0×60.350076UL / FM
4" × 2-1/2"DN100×65108.0×76.150076UL / FM
4" × 3"DN100×80108.0×88.950076UL / FM
4" × 1/2"DN100×15114.3×21.350076UL / FM / VdS
4" × 3/4"DN100×20114.3×26.950076UL / FM / VdS
4" × 1"DN100×25114.3×33.750076UL / FM / VdS
4" × 1-1/4"DN100×32114.3×42.450076UL / FM / VdS
4" × 1-1/2"DN100×40114.3×48.350076UL / FM / VdS / LPCB
4" × 2"DN100×50114.3×60.350076UL / FM / VdS / LPCB
4" × 2-1/2"DN100×65114.3×73.050076UL / FM
4" × 2-1/2"DN100×65114.3×76.150076UL / FM / VdS / LPCB
4" × 3"DN100×80114.3×88.950076UL / FM / VdS / LPCB
5" × 3/4"DN125×20139.7×26.950089UL / FM
5" × 1-1/2"DN125×40133.0×48.350089UL / FM
5" × 1-1/2"DN125×40133.0×60.350089FM
5" × 2-1/2"DN125×65133.0×76.150089UL / FM
5" × 2-1/2"DN125×65133.0×88.950089FM
5" × 1"DN125×25139.7×33.750089UL / FM / VdS
5" × 1-1/4"DN125×32139.7×42.450089UL / FM / VdS
5" × 1-1/2"DN125×40139.7×48.350089UL / FM / VdS
5" × 2"DN125×50139.7×60.350089UL / FM / VdS
5" × 2-1/2"DN125×65139.7×76.150089UL / FM / VdS
5" × 3"DN125×80139.7×88.950089UL / FM / VdS
5" × 4"DN125×100139.7×114.350089UL / FM / VdS / LPCB
5" × 4"DN125×100141.3×114.350089UL / FM
6" × 3/4"DN150×20159.0×26.9500102UL / FM
6" × 1"DN150×25159.0×33.7500102UL / FM
6" × 1-1/4"DN150×32159.0×42.4500102UL / FM
6" × 1-1/2"DN150×40159.0×48.3500102UL / FM
6" × 2"DN150×50159.0×60.3500102UL / FM
6" × 2-1/2"DN150×65159.0×76.1500102UL / FM
6" × 3"DN150×80159.0×88.9500102UL / FM
6" × 4"DN150×100159.0×114.3500102UL / FM
6" × 1/2"DN150×15165.1×21.3500102UL / FM
6" × 3/4"DN150×20165.1×26.9500102UL / FM
6" × 1"DN150×25165.1×33.7500102UL / FM
6" × 1-1/4"DN150×32165.1×42.4500102UL / FM
6" × 1-1/2"DN150×40165.1×48.3500102UL / FM
6" × 2"DN150×50165.1×60.3500102UL / FM
6" × 2-1/2"DN150×65165.1×76.1500102UL / FM
6" × 3"DN150×80165.1×88.9500102UL / FM / LPCB
6" × 4"DN150×100165.1×114.3500102UL / FM
6" × 1"DN150×25168.3×33.7500102UL
6" × 2"DN150×50168.3×60.3500102UL / FM / VdS
8" × 1-1/2"DN200×40219.1×48.3500127UL / FM
8" × 2"DN200×50219.1×60.3500127UL / FM / VdS
8" × 2-1/2"DN200×65219.1×76.1500127UL / FM / VdS
8" × 3"DN200×80219.1×88.9500127UL / FM / VdS / LPCB
8" × 4"DN200×100219.1×114.3500127UL / FM
PROJECT APPROVALS

Approved on projects

112 projects and 77 owners approved this product or its family through the project consultants.

and 100 more projects.

Original approval letters are provided on request with your submittal.

The MECH grooved concentric reducer (thd), model 240N, in ductile iron, sizes 1-1/4″ × 1″ – 8″ × 4″ (DN42×25 – DN200×100), working pressure up to 500 PSI, UL / FM / VdS / LPCB approved depending on size. This guide explains what it does and how it works, compares it with related models, and covers technical data, the critical point in selection and installation, and common mistakes. For more, read the technical library guide.

At a glance

  • A concentric reducer joins two sizes on one centreline.
  • Sizes 1-1/4″ × 1″ – 8″ × 4″ (DN42×25 – DN200×100) — working pressure up to 500 PSI.
  • Approvals: UL / FM / VdS / LPCB (vary by size).
  • Material Ductile iron ASTM A536 Gr. 65-45-12.
  • Designed to ASTM F1548, AWWA C606, ISO 6182-12.

What is a grooved concentric reducer and how does it work?

A concentric reducer joins two sizes on one centreline. The large end is grooved; the small end is grooved or threaded (female or male) depending on the model.

It is used on vertical runs, discharge lines and size changes in networks; the threaded versions connect a grooved line directly to smaller threaded pipe or fittings.

Models in the same family

MECH grooved concentric reducer family
ModelItemSizesMax pressureApprovals
240WMECH GROOVED CONCENTRIC RED MALE (THD)2″ × 1″ – 4″ × 3″500 PSIUL / FM
240XMECH GROOVED CONCENTRIC REDUCER4″ × 2-1/2″ – 12″ × 6″300 PSIUL / FM
240MECH GROOVED CONCENTRIC REDUCER1-1/4″ × 1″ – 24″ × 20″500 PSIUL / FM / VdS / LPCB
240NXMECH GROOVED CONCENTRIC REDUCER (THD)2-1/2″ × 2″ – 8″ × 1″300 PSIUL / FM
240N — this productMECH GROOVED CONCENTRIC REDUCER (THD)1-1/4″ × 1″ – 8″ × 4″500 PSIUL / FM / VdS / LPCB

Technical data

Model 240N specification
ItemSpecification
Design standardASTM F1548, AWWA C606, ISO 6182-12
MaterialDuctile iron ASTM A536 Gr. 65-45-12
CoatingElectrophoretic (std.) — epoxy / hot-dip galvanized optional
Sizes1-1/4″ × 1″ – 8″ × 4″ (DN42×25 – DN200×100)
Approvals and pressure by size
ApprovalsSizesWorking pressure
Not stated in the table1-1/4″ × 1″ – 1-1/2″ × 1″500 PSI
UL / FM / VdS2″ × 1/2″ – 8″ × 2-1/2″500 PSI
UL / FM / VdS / LPCB2″ × 3/4″ – 8″ × 3″500 PSI
UL / FM2-1/2″ × 1″ – 8″ × 4″500 PSI
FM5″ × 1-1/2″ – 5″ × 2-1/2″500 PSI
UL / FM / LPCB6″ × 3″500 PSI
UL6″ × 1″500 PSI

Some sizes come in two pipe outside diameters (for example 73.0 and 76.1 mm for 2-1/2″) depending on the pipe standard; select by the actual outside diameter of your project pipe.

Full dimensions for every size (bolts and more) are in the size table at the top of the page.

Concentric or eccentric?

On a horizontal pump suction an eccentric reducer, flat side up, is normally used so no air collects; the concentric reducer suits vertical runs and discharge lines.

Caution

For threaded versions, check the thread type in the product table or catalogue before ordering.

Installation steps

  1. Check that the pipe ends are grooved to the right dimensions to AWWA C606 (roll or cut groove) and are free of burrs, rust and dirt.
  2. Inspect the gasket and lubricate its outside and lips with the lubricant recommended in the MECH catalogue; never use petroleum-based products with an EPDM gasket.
  3. Fit the gasket over one pipe end, bring the other end or the fitting into place, and slide the gasket so it is centred between the two grooves.
  4. Place both housing halves over the gasket so their keys engage the grooves on both sides.
  5. Hand-tighten the nuts first, making sure each oval-neck bolt sits in its hole, then tighten alternately and evenly to the torque in the MECH installation manual — never exceed it.

The fitting joins with grooved couplings; how the joint is finished (even pad gap or pads meeting) follows the coupling type in the MECH manual.

Full details and bolt torques are in the MECH installation manual among the files on this page.

Common mistakes

  • Letting the gasket lip overhang the pipe end or protrude into a groove, so the gasket is not centred on the joint.
  • Exceeding the specified bolt torque, which can damage the bolt or the joint.
  • Grooves that do not meet AWWA C606 dimensions, or pipe ends that are not square.
  • Tightening the nuts on one side only, so the housing tilts and the key does not seat in the groove.
  • Using petroleum-based lubricant that damages the EPDM gasket.

Files and ordering

On this page: Product page (catalogue), Product page (catalogue), MECH Grooved Fittings & Couplings Catalogue, Installation & operation manual, Material Safety Data Sheet (MSDS). Add the product to your request list with size and quantity and we send a quotation, or build a submittal PDF for the consultant. Fu-Mech is the exclusive MECH agent in Saudi Arabia.

Frequently asked questions

Can I use it on a pump suction?

On a horizontal suction an eccentric reducer is normally preferred; the approved designer’s details govern. See the guide grooved tees, crosses and reducers.

What is the maximum working pressure of model 240N?

Up to 500 PSI. The pressure for each size is in the size table.

Is model 240N UL / FM approved?

Approvals for this model: UL / FM / VdS / LPCB, varying by size as shown in the “Approvals and pressure by size” table above. See also how to verify UL and FM approvals.

What is the gasket material, and does it suit all fluids?

Gasket type and suitable services are given in the MECH catalogue.

Does it suit roll-grooved and cut-grooved pipe?

Grooves are to AWWA C606, rolled or cut; what matters is correct groove dimensions. The difference is explained in the guide roll grooving vs cut grooving.

References

  • ASTM F1548 — Standard Specification for Performance of Fittings for Use with Gasketed Mechanical Couplings Used in Piping Applications
  • AWWA C606 — Grooved and Shouldered Joints
  • ISO 6182-12 — Fire protection — Automatic sprinkler systems — Requirements and test methods for grooved-end components for steel pipe systems
  • ASTM A536 — Standard Specification for Ductile Iron Castings
  • UL 213 — Rubber Gasketed Fittings for Fire-Protection Service
  • FM 1920 — Approval Standard for Pipe Couplings and Fittings for Fire Protection Systems
  • MECH catalogue — Grooved Fittings & Couplings — and installation manual

This guide is general information to help with selection. Figures come from the product data on this page and the MECH catalogue; final design is by the project’s approved designer to NFPA 13 and the project specification.