The MECH dry fire hydrant, model SSF, sizes 6″ (DN150), working pressure 300 PSI (200 / 250 PSI on request), UL 246 / FM 1510 approved. An outdoor fire hydrant fed from the underground main, with two hose outlets and a large pumper outlet. This guide explains what it does and how it works, related models, technical data, the critical point in selection and installation, and common mistakes.
At a glance
- A fire hydrant is an outdoor water supply point for fire crews, installed on the underground main.
- Sizes 6″ (DN150).
- Working pressure 300 PSI (200 / 250 PSI on request).
- Approvals: UL 246 / FM 1510.
- Connection: ASME B16.42 CL150.
- Operating temperature: 0 – 80 °C.
Fire hydrant: what it does and how it works
A fire hydrant is an outdoor water supply point for fire crews, installed on the underground main. Per the product data it has two 2-1/2″ hose outlets and one 4-1/2″ pumper outlet, with outlet threads to NFPA 1963.
A wet-barrel hydrant is always full of water with a valve on each outlet; a dry-barrel hydrant has its main valve below ground, so the barrel drains after closing.
Related models
| Model | Product | Sizes | Pressure | Approvals |
|---|---|---|---|---|
| SSZ2 | WET BARREL FIRE HYDRANT UL/FM RED | — | 300 PSI | UL 246 / FM 1511 / NSF/ANSI 61 |
| SSF-J | MECHANICAL JOINT DRY BARREL FIRE HYDRANT UL/FM | — | 300 PSI | UL 246 / FM 1510 / NSF/ANSI 61 |
| SSF — this product | DRY FIRE HYDRANT | 6″ (DN150) | 300 PSI | UL 246 / FM 1510 |
Technical data
| Item | Specification |
|---|---|
| Design standard | AWWA C502 |
| Connection ends | ASME B16.42 CL150 |
| Nozzle threads | NFPA 1963 |
| Working pressure | 300 PSI (200 / 250 PSI on request) |
| Temperature | 0 – 80 °C |
| Coating | FBE — ANSI/AWWA C550 |
| Approvals | UL 246 / FM 1510 |
| Sizes | 6″ (DN150) |
Dimensions for every size are in the size table at the top of the page.
Wet or dry barrel?
A dry-barrel hydrant (AWWA C502) drains its barrel after closing, used where freezing or damage is a concern; a wet-barrel hydrant (AWWA C503) is simpler with each outlet independent. The designer selects the type per the project specification and the authority having jurisdiction.
Caution
Outlet threads must match the local fire department couplings; confirm the required thread before ordering.
Installation steps
- Install on a branch from the underground main with an isolating valve per the project details.
- Seat the base on a concrete thrust block; for a dry hydrant leave gravel around the base for drainage.
- Face the pumper outlet toward the road and keep clear space around the hydrant.
- Flush and pressure / flow test the hydrant after installation.
Common mistakes
- Outlet threads that do not match fire department couplings.
- No thrust block, or no drainage at a dry hydrant base.
- Placing the hydrant where fire trucks cannot reach it.
Files and ordering
On this page: Product page (catalogue), Installation & operation manual, MECH Fire Protection Valves Catalogue (UL/FM), Material Safety Data Sheet (MSDS). Add the product to your request list with size and quantity and we send a quotation, or build a submittal PDF for the consultant. Fu-Mech is the exclusive MECH agent in Saudi Arabia.
Frequently asked questions
How many outlets does it have?
Two 2-1/2″ hose outlets and one 4-1/2″ pumper outlet, per the product data.
Is it suitable for potable water?
Some models carry NSF/ANSI 61 as shown in their approvals; check the model you need.
What is the working pressure of model SSF?
300 PSI (200 / 250 PSI on request) per the product data. The pressure for each size or listed model is in the size table and datasheet.
What approvals does it carry?
UL 246 / FM 1510 per the product data. Check the size and listed model in the approval listings, and see how to verify UL and FM approvals.
What end connection does it have?
ASME B16.42 CL150. Choose the connection that matches the adjacent pipe and fittings.
References
- AWWA C502 — Dry-Barrel Fire Hydrants
- NFPA 1963 — Standard for Fire Hose Connections
- ASME B16.42 — Ductile Iron Pipe Flanges and Flanged Fittings: Classes 150 and 300
- AWWA C550 — Protective Interior Coatings for Valves and Hydrants
- UL 246 — Hydrants for Fire-Protection Service
- MECH catalogue — Fire fighting valves
This guide is general information to help with selection. Figures come from the product data on this page and the MECH catalogue; final design is by the project’s approved designer to the applicable standards and the project specification.