The MECH butterfly valve flanged lever, model D71X4, sizes 1.5″ – 32″ (DN40 – DN800), working pressure 300 PSI. A lever-operated butterfly valve for water networks and general services. This guide explains what it does and how it works, related models, technical data, the critical point in selection and installation, and common mistakes. For more, read the guide butterfly valves in fire protection.
At a glance
- A butterfly valve controls flow with a disc that rotates on a shaft inside the body: parallel to the flow when open, across it when closed.
- Sizes 1.5″ – 32″ (DN40 – DN800).
- Working pressure 300 PSI.
- Connection: ASME B16.1 CL125, ASME B16.5 CL150.
- Operating temperature: 0 – 80 °C.
Butterfly valve: what it does and how it works
A butterfly valve controls flow with a disc that rotates on a shaft inside the body: parallel to the flow when open, across it when closed. It is driven by a handwheel gear operator so it closes slowly, with an indicator showing its position (open / shut).
This model is for water, HVAC and general services (blue), operated by a lever that locks in several open positions. Its top flange is to ISO 5211, so an actuator can be fitted when needed.
Related models
| Model | Product | Sizes | Pressure | Approvals |
|---|---|---|---|---|
| D71X4 — this product | BUTTERFLY VALVE FLANGED LEVER | 1.5″ – 32″ (DN40 – DN800) | 300 PSI | — |
| D371X205 | WAFER BUTTERFLY VALVE BLUE | 2″ – 24″ (DN50 – DN600) | 300 PSI | — |
Technical data
| Item | Specification |
|---|---|
| Design standard | MSS SP-67 |
| Connection ends | ASME B16.1 CL125, ASME B16.5 CL150 |
| Top flange | ISO 5211 |
| Working pressure | 300 PSI |
| Temperature | 0 – 80 °C |
| Coating | FBE — ANSI/AWWA C550 |
| Sizes | 1.5″ – 32″ (DN40 – DN800) |
Dimensions for every size are in the size table at the top of the page.
Disc clearance when open
When open, the disc projects beyond the body on both sides. Fitted directly against a check valve, strainer or narrow fitting it may strike it and not open fully. Check the disc dimensions on the datasheet and add a spacer where needed.
Caution
Close the valve slowly to avoid water hammer on large lines.
Installation steps
- Check the end type (wafer, grooved or threaded) and flange standard match the line.
- Open the valve slightly before fitting so the seat is not damaged, then install between flanges or with grooved couplings as applicable.
- Check disc clearance with adjacent fittings, then cycle the valve fully open and shut after installation.
Common mistakes
- Fitting it against a component the disc strikes.
- Tightening flange bolts with the valve fully shut, damaging the seat.
- Slamming it shut on a large line, causing water hammer.
Files and ordering
On this page: Product datasheet, MECH Water Valves Catalogue, Material Safety Data Sheet (MSDS). Add the product to your request list with size and quantity and we send a quotation, or build a submittal PDF for the consultant. Fu-Mech is the exclusive MECH agent in Saudi Arabia.
Frequently asked questions
Why is it gear-operated?
Fast closure causes water hammer, and standards require indicating control valves to close slowly. The gear operator slows the movement and shows the position.
Can an electric actuator be fitted?
Yes, the top flange is to ISO 5211 and takes standard actuators.
What is the working pressure of model D71X4?
300 PSI per the product data. The pressure for each size or listed model is in the size table and datasheet.
What end connection does it have?
ASME B16.1 CL125, ASME B16.5 CL150. Choose the connection that matches the adjacent pipe and fittings.
References
- ASME B16.1 — Gray Iron Pipe Flanges and Flanged Fittings
- ASME B16.5 — Pipe Flanges and Flanged Fittings
- MSS SP-67 — Butterfly Valves
- AWWA C550 — Protective Interior Coatings for Valves and Hydrants
- ISO 5211 — Industrial valves — Part-turn actuator attachments
- MECH catalogue — Fire fighting valves
This guide is general information to help with selection. Figures come from the product data on this page and the MECH catalogue; final design is by the project’s approved designer to the applicable standards and the project specification.