The MECH pressure reducing valve flanged blue, model SK720X, sizes 2″ – 24″ (DN50 – DN600), working pressure PN10 / PN16 / PN25. It reduces network pressure to a steady lower downstream pressure regardless of inlet changes. This guide explains what it does and how it works, related models, technical data, the critical point in selection and installation, and common mistakes. For more, read the guide pressure reducing vs relief valves.
At a glance
- A pressure reducing valve lowers downstream pressure to a set value and holds it as inlet pressure and demand change, protecting fixtures and pipework on lower floors and high-pressure zones.
- Sizes 2″ – 24″ (DN50 – DN600).
- Working pressure PN10 / PN16 / PN25.
- Connection: Flange BS EN 1092-2.
- Operating temperature: 0 – 80 °C.
Pressure reducing valve: what it does and how it works
A pressure reducing valve lowers downstream pressure to a set value and holds it as inlet pressure and demand change, protecting fixtures and pipework on lower floors and high-pressure zones.
The outlet pressure is set with the adjusting screw to suit the zone, and the valve is normally fitted with an upstream strainer, gauges and isolating valves.
Technical data
| Item | Specification |
|---|---|
| Design standard | CJ/T 219, CJ/T 256, JB/T 10674, BS EN 558 series 10 |
| Connection ends | Flange BS EN 1092-2 |
| Working pressure | PN10 / PN16 / PN25 |
| Temperature range | 0 – 80 °C |
| Sizes | 2″ – 24″ (DN50 – DN600) |
Dimensions for every size are in the size table at the top of the page.
Setting and debris protection
Fit a strainer upstream because debris spoils the seat, and set outlet pressure under real flow while reading the downstream gauge.
Caution
A reducing valve is not a safety valve; if downstream equipment cannot take inlet pressure, add a relief valve per the design.
Installation steps
- Fit an isolating valve and strainer upstream and an isolating valve downstream.
- Install with the arrow in the direction of flow.
- Fit pressure gauges upstream and downstream.
- Set outlet pressure under flow, then tighten the locknut.
Common mistakes
- Installing it without an upstream strainer.
- Setting it at no flow, so pressure drifts in use.
- Treating it as a safety valve.
Files and ordering
On this page: Product datasheet, Additional technical data, Installation & operation manual, MECH Water Valves Catalogue, Material Safety Data Sheet (MSDS). Add the product to your request list with size and quantity and we send a quotation, or build a submittal PDF for the consultant. Fu-Mech is the exclusive MECH agent in Saudi Arabia.
Frequently asked questions
What is the difference between a reducing and a relief valve?
A reducing valve continuously controls downstream pressure; a relief valve only opens when pressure exceeds a limit. See pressure reducing vs relief valves.
How is it set?
With the adjusting screw under flow, reading the downstream gauge.
What is the working pressure of model SK720X?
PN10 / PN16 / PN25 per the product data. The pressure for each size or listed model is in the size table and datasheet.
What end connection does it have?
Flange BS EN 1092-2. Choose the connection that matches the adjacent pipe and fittings.
References
- BS EN 1092-2 — Flanges and their joints — Cast iron flanges, PN designated
- BS EN 558 — Industrial valves — Face-to-face and centre-to-face dimensions of metal valves
- MECH catalogue — Product datasheet
This guide is general information to help with selection. Figures come from the product data on this page and the MECH catalogue; final design is by the project’s approved designer to the applicable standards and the project specification.